Contents

FIELDCONTROLS HUMIDIFIERS AN 135 Thermistor Probe Replacement Instructions SUPPLEMENT TO THE ELECTRONIC STEAM POWER HUMIDIFIERS MODEL S2000 AND S2020 REPAIRS SHOULD BE PERFORMED BY A QUALIFIED TECHNICIAN To replace the Thermistor Probe in the S series steam humidifier you must unplug and shut down your steam humidifier and allow it to cool The water tank must be drained the water supply drain lines and electrical wiring must be disconnected and the unit removed from the duct Pull straight up on the Green terminal block to disconnect it from the unit Place the unit on a flat working surface Using a phillips screwdriver remove the two screws that hold the baffle plate to the tank Lift the baffle slightly back to clear the water level probe a ...